Título: Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography
Autor(es): Takeshita, Wilton Mitsunari
Iwaki, Lilian Cristina Vessoni
Silva, Mariliani Chicarelli Da
Iwaki Filho, Liogi
Queiroz, Alfredo De Franco
Geron, Lucas Bachegas Gomes
Data do documento: Set-2013
Resumo: Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR‑CMOS), four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR) in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360) were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC) curve (Az) were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively). The highest values were found for 1‑mm drills and the lowest for 0.25‑mm drills, with negative filter having the lowest values of all (Az = 0.631). Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.
Palavras-chave: Filtered images
Digital radiology
Digital subtraction radiography
Digitized X‑rays
Interproximal caries
ISSN: 0976-2361
Parte de : Contemporary Clinical Dentistry
Idioma: eng
Instituição/Editora: Medknow Publications and Media Pvt. Ltd.
Citação: TAKESHITA, W. M. et al. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography. Contemporary Clinical Dentistry, Mumbai, v. 4, n. 3, p. 338-342, jul./set. 2013. Disponível em: https://journals.lww.com/cocd/fulltext/2013/04030/comparison_of_the_diagnostic_accuracy_of_direct.12.aspx. Acesso em: 6 jan. 2026.
Licença: Creative Commons Atribuição-NãoComercial-CompartilhaIgual 4.0 Internacional (CC BY-NC-SA 4.0)
URI: https://ri.ufs.br/jspui/handle/riufs/24127
Aparece nas coleções:DOD - Artigos de periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DiagnosticAccuracyDirectDigitalRadiographySystem.pdf876,69 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.