Por favor, use este identificador para citar o enlazar este ítem: https://ri.ufs.br/jspui/handle/riufs/1092
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorFaria e Silva, André Luis-
dc.contributor.authorLima, Adriano F.-
dc.contributor.authorMoraes, Rafael Ratto de-
dc.contributor.authorMartins, Luis Roberto Marcondes-
dc.contributor.authorPiva, Evandro Lima-
dc.date.accessioned2014-08-28T19:57:16Z-
dc.date.available2014-08-28T19:57:16Z-
dc.date.issued2010-11-
dc.identifier.citationFARIA E SILVA, A. L. F. et al. Degree of Conversion of Etch-and-Rinse and Self-etch Adhesives Light-cured Using QTH or LED. Operative Dentistry, Los Angeles, v. 35, n. 6, p. 649-654, 2010. Disponível em: <http://dx.doi.org/10.2341/10-066-L>. Acesso em: 28 ago. 2014.pt_BR
dc.identifier.issn1559-2863-
dc.identifier.urihttps://ri.ufs.br/handle/riufs/1092-
dc.description.abstractIn the current study, the degree of conversion (DC) of bonding agents photoactivated using QTH or LED light-curing units (LCUs) was evaluated by Fourier Transform infrared spectroscopy with an attenuated total reflectance (ATR) device. Four LCUs were evaluated: one QTH (Optilux 501; Demetron Kerr) and three LEDs: Radii Cal (SDI), Elipar FreeLight 2 (3MESPE) and Bluephase (Ivoclar Vivadent). Two etch-and-rinse (Scotchbond Multi-Purpose SBMP and Single Bond 2–SB2) and two self-etch adhesives (Clearfil SE Bond–CSE, and Clearfil S3 Bond–CS3) were tested. For SBMP and CSE, the primer was not used. The irradiance and spectral emission of the LCUs were obtained with a radiometer and spectrometer. The materials were placed onto the ATR cell as thin films, the solvent was evaporated (when necessary) and photoactivation was carried out for 20 seconds. The DC (%) was evaluated after five minutes (n=5). The data were statistically analyzed (p<0.05). The irradiance for Optilux, Radii, FreeLight 2 and Bluephase was 760, 600, 1000 and 1100 mW.cm-2, respectively. The wavelength of emission for Optilux was between 375 and 520 nm (peak at 496 nm), while for Radii, it was between 420 and 520 nm (peak at 467 nm) Freelight 2 presented an emission spectrum between 415 and 520 nm, and for Bluephase, it was between 410 and 530 nm, both having a peak at 454 nm. SB2 generally showed higher DC com pared with the other bonding agents. When cured using the QTH unit, the DC results were SB2=CS3>CSE>SBMP; for all LEDs, the DC results showed SB2>CSE>SBMP>CS3. For SB2, the highest DC was observed when the material was cured with Radii, while there were no significant differences among the other LCUs. CSE and CS3 showed higher DC when cured using the QTH unit, but similar results were observed among the LEDs. For SBMP, no significant differences among the LCUs were detected. In conclusion, the combination bonding agent vs curing unit had a significant effect on DC, mainly for the self-etch adhesives.pt_BR
dc.language.isoenpt_BR
dc.publisherAcademy of Operative Dentistrypt_BR
dc.subjectConversão (GC)pt_BR
dc.subjectFilmes finospt_BR
dc.subjectSolventept_BR
dc.titleDegree of Conversion of Etch-and-Rinse and Self-etch Adhesives Light-cured Using QTH or LEDpt_BR
dc.typeArtigopt_BR
dc.identifier.licenseAutorização para publicação no Repositório Institucional da Universidade Federal de Sergipe (RIUFS) concedida pelo editorpt_BR
Aparece en las colecciones: DOD - Artigos de periódicos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
DegreeOfConversion.pdf172,57 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.