Use este identificador para citar ou linkar para este item: https://ri.ufs.br/jspui/handle/riufs/21542
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLima, Leonardo Lelis de-
dc.contributor.authorOliveira, Raquel Aline Pessoa-
dc.contributor.authorLima, Héstia Raissa Batista Reis-
dc.contributor.authorSantos, Hamona Novaes dos-
dc.contributor.authorSantos, José Osman dos-
dc.contributor.authorLima, Adilmo Francisco de-
dc.contributor.authorSouza, Susana Oliveira de-
dc.date.accessioned2025-04-03T23:35:53Z-
dc.date.available2025-04-03T23:35:53Z-
dc.date.issued2010-
dc.identifier.citationLIMA, L. L. et al. Thermoluminescent properties studies of spodumene lilac sample to dosimetric applications. Journal of Physics: Conference Series, v. 249, 2010. Trabalho apresentado em 16º International Conference on Defects in Insulating Materials, 2008, [Aracaju]. Disponível em: https://iopscience.iop.org/article/10.1088/1742-6596/249/1/012013/pdf. Acesso em: 3 abr. 2025.pt_BR
dc.identifier.issn1742-6596-
dc.identifier.issn1742-6588-
dc.identifier.urihttps://ri.ufs.br/jspui/handle/riufs/21542-
dc.languageengpt_BR
dc.publisherIOP Publishingpt_BR
dc.relation.ispartofJournal of Physics: Conference Seriespt_BR
dc.subjectThermoluminescent propertieseng
dc.subjectSpodumeneeng
dc.titleThermoluminescent properties studies of spodumene lilac sample to dosimetric applicationspt_BR
dc.typeTrabalhos em Eventospt_BR
dc.identifier.licenseCreative Commons Atribuição 4.0 Internacional (CC BY 4.0)pt_BR
dc.description.resumoThis work investigates the thermoluminescent (TL) dosimetric properties in natural spodumene, LiAlSi2O6, called kunzite, from Minas Gerais State, Brazil. The mineralogical and chemical composition of this material was identified by means X-ray fluorescence and X-ray diffraction. Some dosimetric properties were studied, such as thermoluminescent emission curves as function of gamma dose. The glow curves of annealed kunzite presented two very intense TL peaks at 215 °C (peak II) and 350 °C (peak III), after gamma irradiation, being both of first kinetic order. These two most prominent peaks analyzed do not presented a linear growth in the range of 50 to 5000 Gy in the range of doses studied. The peak II also presented a very short calculated lifetime, which means it is hardly can be used in dosimetry, while the peak III has a longer lifetime and could be used in some applications for high doses dosimetry.pt_BR
Aparece nas coleções:DFI - Artigos de periódicos
DFI - Trabalhos apresentados em eventos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ThermoluminescentPropertiesSpodumene.pdf418,61 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.