Use este identificador para citar ou linkar para este item:
https://ri.ufs.br/jspui/handle/riufs/24570| Tipo de Documento: | Artigo |
| Título: | Does maintaining a bottle of adhesive without the lid significantly reduce the solvent content? |
| Autor(es): | Santana, Márcia Luciana Carregosa Júnior, José Aginaldo de Sousa Leal, Pollyana Caldeira Faria e Silva, André Luis |
| Data do documento: | 2014 |
| Resumo: | This study aimed to evaluate the effect of maintaining a bottle of adhesive without its lid on the solvent loss of the etch-and-rinse adhesive systems. Three 2-step etch-and-rinse adhesives with different solvents (acetone, ethanol or butanol) were used in this study. Drops of each adhesive were placed on an analytical balance and the adhesive mass was recorded until equilibrium was achieved (no significant mass alteration within time). The solvent content of each adhesive and evaporation rate of solvents were measured (n=3). Two bottles of each adhesive were weighted. The bottles were maintained without their lids for 8 h in a stove at 37 ºC, after which the mass loss was measured. Based on mass alteration of drops, acetone-based adhesive showed the highest solvent content (46.5%, CI 95%: 35.8-54.7) and evaporation rate (1.11 %/s, CI95%: 0.63-1.60), whereas ethanol-based adhesive had the lowest values (10.1%, CI95%: 4.3-16.0; 0.03 %/s CI95%: 0.01-0.05). However, none of the adhesives bottles exhibited significant mass loss after sitting for 8 h without their lids (% from initial content; acetone - 96.5, CI 95%: 91.8- 101.5; ethanol - 99.4, CI 95%: 98.4-100.4; and butanol - 99.3, CI 95%: 98.1-100.5). In conclusion, maintaining the adhesive bottle without lid did not induce significant solvent loss, irrespective the concentration and evaporation rate of solvent. |
| Palavras-chave: | Adhesives Solvents Volatilization |
| ISSN: | 1806-4760 |
| Parte de : | Brazilian Dental Journal |
| Idioma: | eng |
| Instituição/Editora: | Fundação Odontológica de Ribeirão Preto |
| Citação: | SANTANA, M. L. C. et al. Does maintaining a bottle of adhesive without the lid significantly reduce the solvent content? Brazilian Dental Journal, Ribeirão Preto, v. 25, n. 6, p. 543-545, 2014. Disponível em: https://www.scielo.br/j/bdj/a/VncrK3PLTkG97NqSkgxmRMD/?lang=en. Acesso em: 10 fev. 2026. |
| Licença: | Creative Commons Atribuição-NãoComercial 3.0 Não Adaptada (CC BY-NC 3.0) |
| Identificador: | https://doi.org/10.1590/0103-6440201300330 |
| URI: | https://ri.ufs.br/jspui/handle/riufs/24570 |
| Aparece nas coleções: | DFS - Artigos de periódicos DOD - Artigos de periódicos |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| BottleAdhesiveWithoutLid.pdf | 134,07 kB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.
