Use este identificador para citar ou linkar para este item:
https://ri.ufs.br/jspui/handle/riufs/24626Registro completo de metadados
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.contributor.author | Takeshita, Wilton Mitsunari | - |
| dc.contributor.author | Iwaki, Lilian Cristina Vessoni | - |
| dc.contributor.author | Silva, Mariliani Chicarelli da | - |
| dc.contributor.author | Tonin, Renata Hernandes | - |
| dc.date.accessioned | 2026-02-23T20:40:01Z | - |
| dc.date.available | 2026-02-23T20:40:01Z | - |
| dc.date.issued | 2014-09 | - |
| dc.identifier.citation | TAKESHITA, W. M. et al. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss. Contemporary Clinical Dentistry, Mumbai, v. 5, n. 3, p. 318-323, jul./set. 2014. Disponível em: https://journals.lww.com/cocd/fulltext/2014/05030/evaluation_of_diagnostic_accuracy_of_conventional.7.aspx. Acesso em: 23 fev. 2026. | pt_BR |
| dc.identifier.issn | 0976-237X | - |
| dc.identifier.uri | https://ri.ufs.br/jspui/handle/riufs/24626 | - |
| dc.language | eng | pt_BR |
| dc.publisher | Medknow Publications | pt_BR |
| dc.relation.ispartof | Contemporary Clinical Dentistry | pt_BR |
| dc.subject | Alveolar bone loss | eng |
| dc.subject | Cone-beam computerized tomography | eng |
| dc.subject | Conventional periapical radiography | eng |
| dc.subject | Diagnosis | eng |
| dc.subject | Panoramic radiography | eng |
| dc.title | Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss | pt_BR |
| dc.type | Artigo | pt_BR |
| dc.identifier.license | Creative Commons Atribuição-NãoComercial-CompartilhaIgual 4.0 Internacional (CC BY-NC-SA 4.0) | pt_BR |
| dc.description.resumo | Background: To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL). Materials and Methods: ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth – directly on the mandibles (control), using conventional periapical radiography with film holders (Rinn XCP and Han‑Shin), digital periapical radiography with complementary metal‑oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT). Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA), Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health®, Rochester, NY, USA), and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey’s test at 5% significance level. Results: The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P < 0.0001). CBCT differed from panoramic (P = 0.0130), periapical with Rinn XCP (P = 0.0066), periapical with Han-Shin (P < 0.0001), and digital periapical (P = 0.0027). Conventional periapicals with film holders differed from each other (P = 0.0007). Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004). Conclusions: Conventional periapical with Han‑Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls. | pt_BR |
| dc.description.local | Mumbai | pt_BR |
| dc.identifier.doi | https://doi.org/10.4103/0976-237X.137930 | - |
| Aparece nas coleções: | DOD - Artigos de periódicos | |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| DiagnosticAccuracyConventionalDigitalPeriapicalRadiography.pdf | 704,11 kB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.
