Use este identificador para citar ou linkar para este item: https://ri.ufs.br/jspui/handle/riufs/25233
Tipo de Documento: Artigo
Título: Comparison of the placebo effect between different non-penetrating acupuncture devices and real acupuncture in healthy subjects: a randomized clinical trial
Autor(es): Maciel, Leonardo Yung dos Santos
Leite, Paula Michele dos Santos
Poderoso Neto, Mauricio Lima
Mendonça, Andreza Carvalho Rabelo
Araujo, Carla Carolina Alves de
Souza, Jersica da Hora Santos
DeSantana, Josimari Melo
Data do documento: 2016
Resumo: Background: Several studies have used placebo acupuncture methods in recent years as a way for blinding therapeutic effect of acupuncture, however placebo method selection has not followed enough methodological criteria to the point of stabilishing a consensus of what should be the best method to be used. This study aimed to evaluate the effectiveness of three different placebo acupuncture methods for blinding applied in healthy subjects. Methods: This study was approved by the Ethics Committee of the Federal University of Sergipe with the number 47193015.5.0000.5546 and all individuals participating in the study signed a free and informed consent. For this study, 321 healthy volunteers were randomly divided into seven groups using the abdominal point stomach (ST) 25 and seven groups using the lumbar point bladder (Bl) 52 for stimulation. For real acupuncture procedure, three different methods of placebo acupuncture plus a mix between real acupuncture and placebo applied in the same individual, totaling fourteen groups in this study. Outcome assessments were performed before and immediately after applying the technique. Investigator who assessed variables had no knowledgement about the method was applied. Identification, weight and height were measured before puncture by using. At the end, subjects were asked if they believed they were receiving real or placebo acupuncture. Results: There was no significant difference between groups for the perception about the type o stimulation (wheter real or placebo puncture). Percentage of subjects who reported to have received real acupuncture in the abdominal point was 69.56% in real group, 86.95% in group Park Sham, 82.60% in needle + foam, 91.30% in insertion and removal, 78.26% in real + Park Sham, 86.36% in real + needle and foam, 86.95% in real + insertion and removal, and for the lumbar point was 86.36% in real group, 86.95% in group Park Sham, 69.56% in needle + foam, 72% in insertion and removal, 86.95% in real + Park Sham, 81.81% in real + needle and foam and 78.26% in real + insertion and removal. Conclusion: All placebo acupuncture methods proposed in this study were equally effective for bliding the study participants using either abdominal or lumbar acupoints, and none of the placebo methods presented benefit compared to the other to be used in future clinical trials.
Palavras-chave: Acupuncture
Placebo
Acupuncture points
Healthy volunteers
ISSN: 2662-7671
Parte de : BMC Complementary and Alternative Medicine
Idioma: eng
Instituição/Editora: BioMed Central
Citação: MACIEL, L. Y. S. et al. Comparison of the placebo effect between different non-penetrating acupuncture devices and real acupuncture in healthy subjects: a randomized clinical trial. BMC Complementary and Alternative Medicine, London, v. 16, n. 518, 2016. Disponível em: https://link.springer.com/article/10.1186/s12906-016-1477-2. Acesso em: 18 jun. 2026.
Licença: Creative Commons Atribuição 4.0 Internacional (CC BY 4.0)
Identificador: https://doi.org/10.1186/s12906-016-1477-2
URI: https://ri.ufs.br/jspui/handle/riufs/25233
Aparece nas coleções:PPGCS - Artigos de periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ComparisonPlaceboEffectNonPenetratingAcupunctureDevices.pdf1,12 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.