Use este identificador para citar ou linkar para este item:
https://ri.ufs.br/jspui/handle/riufs/25496| Tipo de Documento: | Artigo |
| Título: | Efeito da remoção e reinserção de hastes tipo force-closed nas deformações da artroplastia total de quadril |
| Título(s) alternativo(s): | Effect of removal and reinsertion of force-closed stems on deformation of total hip arthroplasty |
| Autor(es): | Griza, Sandro Gomes, Luiz Sérgio Marcelino Cervieri, André Strohaecker, Telmo Roberto |
| Data do documento: | 2016 |
| Resumo: | Objetivos: Estudo da remoção de haste do tipo force‐closed e a sua reinserção posterior para aumentar a exposição do acetábulo durante a revisão. Não é conhecido o quanto esse procedimento modifica a interface haste/cimento. Métodos: Três modelos de hastes afiladas foram implantadas em fêmures compósitos. Extensômetros de deformação foram embebidos no aspecto medial do manto de cimento e em diversas posições sobre a superfície externa dos fêmures. As deformações foram medidas durante cargas estáticas, as quais foram aplicadas em dois diferentes momentos: após a implantação e após um milhão de ciclos de carga, seguido pela remoção e reinserção. O teste t foi feito. As diferenças entre as deformações foram confrontadas com p ≤ 0,05 entre os dois momentos de carga estática e entre os três projetos de hastes. Resultados: Não foram encontradas diferenças significativas nas deformações após os dois momentos de carga para os três modelos. Não foram encontradas diferenças significativas nas deformações iniciais dos três modelos para a maioria dos extensômetros aderidos aos fêmures. Conclusões: A reinserção de haste do tipo force‐closed não altera a transmissão de carga da haste para o cimento e para a superfície do fêmur, mesmo após um milhão de ciclos. |
| Abstract: | Objectives: This study investigated removal of a force-closed stem, done in order to improve acetabular exposure during revision, with reinsertion afterwards. It is unknown how much this procedure modifies the stem/cement interface. Methods: Three tapered stem models were implanted into composite femurs. Strain gauges were embedded in the medial aspect of the cement mantle and in several positions on the outer surface of the femurs. The deformation was measured during static loading, which was applied at two different times: after implantation and after one million loading cycles, followed by stem removal and reinsertion. The t test was performed. The differences in deformation were compared (at p ≤ 0.05) between the two static loading times and among the three stem designs. Results: No significant differences in deformation were found after the two loading times for the three models. No significant differences in the initial deformations of the three models were found for most of the gauges attached to the femurs. Conclusions: Reinsertion of the force-closed stem does not alter the load transmission from the stem to the cement and to the surface ofthe femur, even after one million loading cycles. |
| Palavras-chave: | Artroplastia de quadril Desenho de prótese Fenômenos mecânicos Hip arthroplasty Prosthesis design Mechanical phenomena |
| ISSN: | 1982-4378 |
| Parte de : | Revista Brasileira de Ortopedia |
| Idioma: | por |
| Instituição/Editora: | Sociedade Brasileira de Ortopedia e Traumatologia |
| Citação: | GRIZA, S. et al. Efeito da remoção e reinserção de hastes tipo force-closed nas deformações da artroplastia total de quadril. Revista Brasileira de Ortopedia, São Paulo, v. 51, n. 1, p. 29–35, 2016. Disponível em: https://www.sciencedirect.com/science/article/pii/S0102361615001174?via%3Dihub. Acesso em: 9 jul. 2026. |
| Licença: | Creative Commons Atribuição-Não Comercial-Sem Derivações 4.0 Internacional (CC BY-NC-ND 4.0) |
| Identificador: | https://doi.org/10.1016/j.rbo.2015.03.008 |
| URI: | https://ri.ufs.br/jspui/handle/riufs/25496 |
| Aparece nas coleções: | DCEM - Artigos de periódicos |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| EfeitoRemocaoReinsercaoHastesArtoplastiaTotal.pdf | 991,85 kB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.