Use este identificador para citar ou linkar para este item:
https://ri.ufs.br/jspui/handle/riufs/25622Registro completo de metadados
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.contributor.author | Santos, William de Souza | - |
| dc.contributor.author | Gonalves, P. E. | - |
| dc.contributor.author | Belinato, Walmir | - |
| dc.contributor.author | Caldas, Linda Viola Ehlin | - |
| dc.contributor.author | Perini, Ana Paula | - |
| dc.contributor.author | Neves, Lucio Pereira | - |
| dc.date.accessioned | 2026-07-21T19:10:29Z | - |
| dc.date.available | 2026-07-21T19:10:29Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.citation | SANTOS, W. S. et al. The influence of different 192Ir sources geometries to the energy deposition. Journal of Physics: Conference Series, Bento Gonçalves, v. 733, nov./dez. 2016. Disponível em: https://iopscience.iop.org/article/10.1088/1742-6596/733/1/012092. Acesso em: 21 jul. 2026. | pt_BR |
| dc.identifier.issn | 1742-6596 | - |
| dc.identifier.uri | https://ri.ufs.br/jspui/handle/riufs/25622 | - |
| dc.language | eng | pt_BR |
| dc.publisher | IOP Publishing | pt_BR |
| dc.relation.ispartof | Journal of Physics: Conference Series | pt_BR |
| dc.subject | HDR source | eng |
| dc.subject | VariSource classic model | eng |
| dc.subject | Monte Carlo simulations | eng |
| dc.subject | 192Ir sources | eng |
| dc.title | The influence of different 192Ir sources geometries to the energy deposition | pt_BR |
| dc.type | Artigo | pt_BR |
| dc.identifier.license | Creative Commons Atribuição 3.0 Não Adaptada (CC BY 3.0) | pt_BR |
| dc.description.resumo | In this paper, various simplifications of the HDR source Varian VariSource Classic model, in which 192Ir as a radionuclide is used, were compared. These simplifications were carried out by Monte Carlo simulations, using the MCNPX 2.7.0 code. The different sources were compared through a distribution of energy deposition in a water phantom. Our results indicated that small simplifications will present no influence on the source response, and the removal of the entire capsule surrounding the radionuclide will present a difference of just 0.53% in the final response. | pt_BR |
| dc.description.local | Bento Gonçalves | pt_BR |
| dc.identifier.doi | https://doi.org/10.1088/1742-6596/733/1/012092 | - |