Use este identificador para citar ou linkar para este item: https://ri.ufs.br/jspui/handle/riufs/494
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorMaia, Ana Figueiredo-
dc.contributor.authorOliveira, K. M.-
dc.contributor.authorAlves, Douglas Rafael Mendes-
dc.contributor.authorSilva, Davi Alves da-
dc.date.accessioned2013-05-03T18:01:10Z-
dc.date.available2013-05-03T18:01:10Z-
dc.date.issued2008-11-
dc.identifier.citationMAIA, A. F. et al. Dosimetria do paciente em radiodiagnóstico. Scientia Plena, Aracaju, v. 4, n. 11, nov. 2008. Disponível em: <http://www.scientiaplena.org.br/ojs/index.php/sp/article/viewFile/715/368>. Acesso em: 3 maio 2013.pt_BR
dc.identifier.issn1808-2793-
dc.identifier.urihttps://ri.ufs.br/handle/riufs/494-
dc.description.abstractNas aplicações de radiação X para obtenção de imagens, deve-se buscar uma dose reduzida no paciente e uma imagem de qualidade. Neste projeto, desenvolveu-se uma metodologia para avaliação da qualidade de imagens radiográficas e dos níveis de kerma no ar na entrada na pele no Setor de Radiologia de um hospital público do estado de Sergipe. Para tanto, foram desenvolvidos três formulários, baseados em uma norma da comunidade européia, que permitiram uma avaliação da imagem e a obtenção das técnicas utilizadas durante os exames. Realizou-se também um controle das radiografias rejeitadas, para determinação do índice de rejeitos real e das principais causas de rejeição. Foi possível fazer um panorama geral da qualidade das imagens radiográficas obtidas no serviço de radiologia avaliado e, com isso, identificar aspectos de melhoria.______________________________________________________________________________________ ABSTRACT: In image processes using X radiation, it is necessary to look for a commitment between low patient dose and image quality. In this study, the image quality and the patient dose in a Radiology department of a public hospital were evaluated. For that, three questionnaires, based on European community publications, were developed for allowing an evaluation of the image quality and for getting the techniques used during the examinations, which were necessary for the dose calculation. A control of the rejected X rays was also performed. The real rate of rejected radiographies and the principal causes of rejection were determinate. The panorama of the service was obtained allowing the identification of aspects of improvement.pt_BR
dc.language.isopt_BRpt_BR
dc.subjectRaios Xpt_BR
dc.subjectControle de qualidadept_BR
dc.subjectDosimetriapt_BR
dc.subjectRadiologiapt_BR
dc.titleDosimetria do paciente em radiodiagnósticopt_BR
dc.typeArtigopt_BR
dc.identifier.licenseAutorização para publicação no Repositório da Universidade Federal de Sergipe (RIUFS) concedida pelo editor.pt_BR
Aparece nas coleções:DFI - Artigos de periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DosimetriaPacienteRadiodiagnóstico.pdf41,55 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.