Use este identificador para citar ou linkar para este item: https://ri.ufs.br/jspui/handle/riufs/15692
Tipo de Documento: Dissertação
Título: Desenvolvimento de sensor eletroquímico baseado em carbon dots suportados em óxido de grafeno reduzido para determinação de hidroxicloroquina
Título(s) alternativo(s): Development of electrochemical sensor based on carbon dots suported on reduced graphene oxide for hydroxychloroquine determination
Autor(es): Santos Junior, José Carlos dos
Data do documento: 28-Jan-2022
Orientador: Sussuchi, Eliana Midori
Coorientador: Rodrigues, Marcelo Oliveira
Resumo: O uso de modificadores em eletrodos de pasta de carbono (EPC) vem crescendo a cada ano, devido à possibilidade de melhorar o desempenho do eletrodo em relação a determinação seletiva de diversos analitos. O objetivo deste trabalho é o desenvolvimento de eletrodos modificados com um material híbrido baseado em carbon dots e óxido de grafeno reduzido (CD-OGr), que possua um baixo custo de preparação, alta sensibilidade e rápida resposta para detecção de hidroxicloroquina. O óxido de grafeno (OG) foi sintetizado pelo método de Hummers modificado, em condições brandas, e reduzido com ácido L-ascórbico para obtenção do óxido de grafeno reduzido (OGr), em seguida os carbon dots foram sintetizados in situ, em matriz de OGr, utilizando como precursores ureia e glicose, por rota hidrotermal a 180 °C por 5 horas. O material híbrido obtido foi caracterizado usando microscopia eletrônica de varredura (MEV), espectroscopia de emissão fluorescente (PL), de absorção molecular na região do ultravioleta-visível (UV-Vis), espetroscopia Raman e vibracional na região do infravermelho por transformada de Fourier (FTIR) além de difratometria de raios x (DRX). Após as caracterizações do CD-OGr o eletrodo de pasta de carbono modificado (ECO) foi aplicado na determinação voltamétrica de hidroxicloroquina em comprimidos comerciais e urina sintética. Os parâmetros como meio eletrolítico, composição do ECO e parâmetros da técnica de voltametria de pulso diferencial, foram otimizados e a caracterização eletroquímica mostrou que o eletrodo ECO apresentou maior sensibilidade na determinação de hidroxicloroquina que o EPC. As otimizações dos parâmetros do meio eletrolítico e da técnica de VPD resultaram em um ganho de corrente expressivo para o sinal analítico da HCQ. Com o desenvolvimento da curva analítica obteve-se os limites de detecção (LD) e quantificação (LQ) de 2,40 pmol∙L-1 e 7,99 pmol∙L-1 , respectivamente, em um intervalo de resposta linear de 19,90 a 138 pmol∙L -1 e a precisão do método desenvolvido mostrou resultados satisfatórios de repetibilidade e reprodutibilidade, apresentando recuperações de 101,55 a 106,83 %, possibilitando o uso do ECO como sensor eletroquímico para a determinação de hidroxicloroquina.
Abstract: The use of modifiers in carbon paste electrodes (CPE) has been growing every year due to the possibility of improving the performance of the electrode in relation to the selective determination of several analytes. The objective of this work is the development of modified electrodes with a hybrid material based on carbon dots and reduced graphene oxide (CD-rGO), which has a low cost of preparation, high sensitivity, and fast response for the determination of hydroxychloroquine. Graphene oxide (GO) was synthesized by the modified Hummer’s method under mild conditions and reduced with L-ascorbic acid to obtain reduced graphene oxide (rGO), then the carbon dots were synthesized in situ, on rGO matrix, using urea and glucose as precursors, by a hydrothermal route at 180 °C for 5 hours. The hybrid material obtained was characterized using scanning electron microscopy (SEM), fluorescence emission spectroscopy (PL), molecular absorption in the ultravioletvisible region (UV-Vis), Raman and vibrational spectroscopy in the Fourier-transform infrared spectroscopy (FTIR), and x-ray diffractometry (XRD). After the characterizations of CD-rGO, the modified carbon paste electrode (ECO) was applied to the voltammetric determination of commercial hydroxychloroquine tablets and synthetic urine. Parameters such as electrolyte medium, ECO composition, and parameters of differential pulse voltammetry technique were optimized and the electrochemical characterization showed that the ECO electrode has higher sensitivity in the hydroxychloroquine determination than CPE. The optimizations of the parameters of the electrolyte medium and the VPD technique resulted in a significant current gain for the analytical signal of HCQ. With the development of the analytical curve, the limits of detection (LOD) and quantification (LOQ) of 2.40 pmol∙L-1 and 7.99 pmol∙L-1 , respectively, were obtained in a linear response range of 19.90 to 138 pmol∙L-1 and the precision of the developed method showed satisfactory results of repeatability and reproducibility, presenting recoveries between 101.55 and 106.83 %, enabling the use of the ECO as an electrochemical sensor for hydroxychloroquine determination.
Palavras-chave: Química
Grafeno
Cloroquina
COVID-19 (doença)
Carbon dots
Hidroxicloroquina
Graphene
Carbon dots
Hydroxychloroquine
área CNPQ: CIENCIAS EXATAS E DA TERRA::QUIMICA
Agência de fomento: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
Idioma: por
Sigla da Instituição: Universidade Federal de Sergipe
Programa de Pós-graduação: Pós-Graduação em Química
Citação: SANTOS JUNIOR, José Carlos dos. Desenvolvimento de sensor eletroquímico baseado em carbon dots suportados em óxido de grafeno reduzido para determinação de hidroxicloroquina. 2022. 93 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, 2022.
URI: https://ri.ufs.br/jspui/handle/riufs/15692
Aparece nas coleções:Mestrado em Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
JOSE_CARLOS_SANTOS_JUNIOR.pdf2,62 MBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.