Use este identificador para citar ou linkar para este item: https://ri.ufs.br/jspui/handle/riufs/23480
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSantos, Thiago de Santana-
dc.contributor.authorGomes, Ana Cláudia Amorim-
dc.contributor.authorMelo, Daniela Guimarães de-
dc.contributor.authorMelo, Auremir Rocha-
dc.contributor.authorCavalcante, Josuel Raimundo-
dc.contributor.authorAraújo, Lorena Cássia Gueiros de-
dc.contributor.authorTravassos, Rosana Maria Coelho-
dc.contributor.authorMartins Filho, Paulo Ricardo Saquete-
dc.contributor.authorPiva, Marta Rabelo-
dc.contributor.authorSilva, Heitor Fontes-
dc.date.accessioned2025-10-14T19:26:08Z-
dc.date.available2025-10-14T19:26:08Z-
dc.date.issued2012-
dc.identifier.citationSANTOS, T. S. et al. Evaluation of reliability and reproducibility of linear measurements of cone-beam-computed tomography. Indian journal of dental research, Mumbai, v. 23, n. 4, p. 473-478, 2012. Disponível em: https://journals.lww.com/ijdr/fulltext/2012/23040/evaluation_of_reliability_and_reproducibility_of.8.aspx. Acesso em: 14 out. 2025.pt_BR
dc.identifier.issn1998-3603-
dc.identifier.urihttps://ri.ufs.br/jspui/handle/riufs/23480-
dc.languageengpt_BR
dc.publisherMedknow Publicationspt_BR
dc.relation.ispartofIndian journal of dental researchpt_BR
dc.subjectCone-beam computed tomographyeng
dc.subjectMandibleeng
dc.subjectReliabilityeng
dc.subjectReproducibilityeng
dc.subjectTopographyeng
dc.titleEvaluation of reliability and reproducibility of linear measurements of cone-beam-computed tomographypt_BR
dc.typeArtigopt_BR
dc.identifier.licenseCreative Commons Atribuição-NãoComercial-CompartilhaIgual 4.0 Internacional (CC BY-NC-SA 4.0)pt_BR
dc.description.resumoObjective: it was to evaluate intra- and interexaminer reliability and reproducibility of linear measurements in cone-beam tomography (CBCT) images. Materials and Methods: CBCT scans were obtained from 50 patients of a private clinic. Two examiners located the landmarks twice in two-dimensional and three-dimensional images on different days, with images performed 1 week apart. Intra- and interexaminer reproducibility and reliability were analyzed. Results: the measurement error (ME) did not show significant differences between intraand interexaminers. The intraclass correlations (ICC) between the intra- and interexaminer readings obtained with the different methods showed almost perfect matches. The results demonstrated high examiner reproducibility for linear and volumetric parameters with high intraclass correlation coefficient (ICC) and coefficient of variation (CV). The ICC showed that the methodology was highly reliable and reproducible (ICC- >0.99 and CV <1.5%). Conclusion: the measurements demonstrated strong agreement between examiners and significant reliability and reproducibility. Therefore, this methodology can serve as a standard for linear measurement analysis of the topography of mandibular canal and osseous adjacent structures.pt_BR
dc.description.localMumbaipt_BR
Aparece nas coleções:DESL - Artigos de periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
EvaluationReliabilityLinearConeBeamTomography.pdf908,07 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.