Use este identificador para citar ou linkar para este item:
https://ri.ufs.br/jspui/handle/riufs/24127| Tipo de Documento: | Artigo |
| Título: | Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography |
| Autor(es): | Takeshita, Wilton Mitsunari Iwaki, Lilian Cristina Vessoni Silva, Mariliani Chicarelli Da Iwaki Filho, Liogi Queiroz, Alfredo De Franco Geron, Lucas Bachegas Gomes |
| Data do documento: | Set-2013 |
| Resumo: | Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR‑CMOS), four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR) in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360) were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC) curve (Az) were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively). The highest values were found for 1‑mm drills and the lowest for 0.25‑mm drills, with negative filter having the lowest values of all (Az = 0.631). Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve. |
| Palavras-chave: | Filtered images Digital radiology Digital subtraction radiography Digitized X‑rays Interproximal caries |
| ISSN: | 0976-2361 |
| Parte de : | Contemporary Clinical Dentistry |
| Idioma: | eng |
| Instituição/Editora: | Medknow Publications and Media Pvt. Ltd. |
| Citação: | TAKESHITA, W. M. et al. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography. Contemporary Clinical Dentistry, Mumbai, v. 4, n. 3, p. 338-342, jul./set. 2013. Disponível em: https://journals.lww.com/cocd/fulltext/2013/04030/comparison_of_the_diagnostic_accuracy_of_direct.12.aspx. Acesso em: 6 jan. 2026. |
| Licença: | Creative Commons Atribuição-NãoComercial-CompartilhaIgual 4.0 Internacional (CC BY-NC-SA 4.0) |
| URI: | https://ri.ufs.br/jspui/handle/riufs/24127 |
| Aparece nas coleções: | DOD - Artigos de periódicos |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| DiagnosticAccuracyDirectDigitalRadiographySystem.pdf | 876,69 kB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.
