Use este identificador para citar ou linkar para este item: https://ri.ufs.br/jspui/handle/riufs/24626
Tipo de Documento: Artigo
Título: Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss
Autor(es): Takeshita, Wilton Mitsunari
Iwaki, Lilian Cristina Vessoni
Silva, Mariliani Chicarelli da
Tonin, Renata Hernandes
Data do documento: Set-2014
Resumo: Background: To evaluate the diagnostic accuracy of different radiographic methods in the assessment of proximal alveolar bone loss (ABL). Materials and Methods: ABL, the distance between cement-enamel junction and alveolar bone crest, was measured in 70 mandibular human teeth – directly on the mandibles (control), using conventional periapical radiography with film holders (Rinn XCP and Han‑Shin), digital periapical radiography with complementary metal‑oxide semiconductor sensor, conventional panoramic, and cone-beam computed tomography (CBCT). Three programs were used to measure ABL on the images: Image tool 3.0 (University of Texas Health Sciences Center, San Antonio, Texas, USA), Kodak Imaging 6.1 (Kodak Dental Imaging 6.1, Carestream Health®, Rochester, NY, USA), and i-CAT vision 1.6.20. Statistical analysis used ANOVA and Tukey’s test at 5% significance level. Results: The tomographic images showed the highest means, whereas the lowest were found for periapical with Han-Shin. Controls differed from periapical with Han-Shin (P < 0.0001). CBCT differed from panoramic (P = 0.0130), periapical with Rinn XCP (P = 0.0066), periapical with Han-Shin (P < 0.0001), and digital periapical (P = 0.0027). Conventional periapicals with film holders differed from each other (P = 0.0007). Digital periapical differed from conventional periapical with Han-Shin (P = 0.0004). Conclusions: Conventional periapical with Han‑Shin film holder was the only method that differed from the controls. CBCT had the closest means to the controls.
Palavras-chave: Alveolar bone loss
Cone-beam computerized tomography
Conventional periapical radiography
Diagnosis
Panoramic radiography
ISSN: 0976-237X
Parte de : Contemporary Clinical Dentistry
Idioma: eng
Instituição/Editora: Medknow Publications
Citação: TAKESHITA, W. M. et al. Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss. Contemporary Clinical Dentistry, Mumbai, v. 5, n. 3, p. 318-323, jul./set. 2014. Disponível em: https://journals.lww.com/cocd/fulltext/2014/05030/evaluation_of_diagnostic_accuracy_of_conventional.7.aspx. Acesso em: 23 fev. 2026.
Licença: Creative Commons Atribuição-NãoComercial-CompartilhaIgual 4.0 Internacional (CC BY-NC-SA 4.0)
Identificador: https://doi.org/10.4103/0976-237X.137930
URI: https://ri.ufs.br/jspui/handle/riufs/24626
Aparece nas coleções:DOD - Artigos de periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DiagnosticAccuracyConventionalDigitalPeriapicalRadiography.pdf704,11 kBAdobe PDFThumbnail
Visualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.