Use este identificador para citar ou linkar para este item:
https://ri.ufs.br/jspui/handle/riufs/23213
Tipo de Documento: | Artigo |
Título: | Breast phantom with silicone implant for evaluation inconventional mammography |
Autor(es): | Silva, Fábio Alessandro Rolemberg Souza, Luiza Freire de Salmon, Carlos Ernesto Garrido Souza, Divanizia do Nascimento |
Data do documento: | 2011 |
Resumo: | With the increased incidence of cancer and a similarly increased number of surgeriesfor insertion of silicone breast implants, it is necessary to assess the effect of suchmaterial within the breast tissue, particularly in mammography, because of the re-duction in the power of breast cancer diagnosis. In this work, we introduce a breastphantom with silicone implants in order to evaluate the influence of the implant onthe visibility of the main mammographic findings: fibers, microcalcifications andtumor masses. In this proposed phantom, the breast tissue was simulated using gelparaffin. In the optical density of phantom mammograms with implants, a reduc-tion in breast tissue visibility was seen corresponding to 23% when compared toa phantom without silicone implants. This poor visibility was due to the X-raybeam scattering on silicone material; this effect produced a loss of visibility in theareas adjacent to the implant. It is expected that the proposed phantom model maybe used as a device for the establishment of a technical standard for these typesof procedures. |
Palavras-chave: | Breast phantom Silicone prostheses Mammography Quality assurance |
ISSN: | 1526-9914 |
Parte de : | Journal of applied clinical medical physics |
Idioma: | eng |
Instituição/Editora: | Wiley on behalf of American Association of Physicists in Medicine |
Citação: | SILVA, F. A. R. et al. Breast phantom with silicone implant for evaluation inconventional mammography, Journal of applied clinical medical physics, Malden, v. 12, n. 1, p. 199-206, 2011. Disponível em: https://aapm.onlinelibrary.wiley.com/doi/epdf/10.1120/jacmp.v12i1.3340. Acesso em: 23 set. 2025. |
Licença: | Creative Commons Atribuição 3.0 Não Adaptada (CC BY 3.0) |
URI: | https://ri.ufs.br/jspui/handle/riufs/23213 |
Aparece nas coleções: | DFI - Artigos de periódicos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
BreastPhantomSiliconeImplantEvaluationMammography.pdf | 518,77 kB | Adobe PDF | ![]() Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.